Last Updated: 09/27/07
Hit Counter

 

 

 

 

  1. Maturity Meters

    Con-Cure™ maturity meters are housed in a protective case. Meters are programmable to allow user-selectable measurement intervals, with a 5 minute interval as default. Once programmed with site-specific data, the meters are activated in the field instantly when a maturity sensor is plugged in. Simultaneous ambient and concrete temperature recording by default. ±0.1°C accuracy. Pre-calibrated. Over 5-years’ battery life in continuous use. (ZoneCure® meters operate on 2 easy-to-replace C-cell batteries. Approx. 30 week life at full usage) All meters can only be used with CMT software and sensors.

    Back to top

     

     

     

  2. Sensors

    All sensors are ready-to-use, epoxy-embedded thermistors, with Qwik-Connect™ technology and are pre-calibrated. Accuracy ±0.1° C. The standard length is 15 ft.

    Back to top

     

     

     

  3. CMT Software

    Con-Cure CMT™ Software to calculate and report concrete strengths based on ASTM C1074, with secure logon and 3 permission levels for administrative control. See Technical Manual for full details. Prints full-color graphs of temperature history, cumulative Time/Temperature Factor (TTF), and strength estimate based on Equivalent Age calculation. Variable parameters include Datum Temperature, Activation Constant, and Specified Temperature. Bi-directional download cable is included. Also includes first year of maintenance.

    Back to top